Welcome to Iightstrade.com!

sunlighting-SL-RPL8Q-W

MOQ : piece

Lead Time : Days

Seller Support : Trade Authenticity Guaranteed & Accepting

Payment : T/T,Western Union

Departure Port : Shenzhen

Product details

Supply Ability

  • Warranty(Year):1 Year

Packaging & Delivery

  • Packaging: piece

Product Specifications

Product Description

 

一.Product and Application:

                                                                

               

   

二.Product description:

 LED panel lights highlighting the use of a new generation of low power and high power SMD LED as light source, has the following characteristics::

 

Energy:

The brightness of the panel light than the equivalent of about 60% reduction in power consumption, power consumption than equivalent incandescent brightness decrease of about 80%, power PFC ≥ 99%, power conversion efficiency ≥ 88%, consistent with energy efficiency standards.

 

Environmental protection:

Infrared and ultraviolet spectrum free, free of harmful substances mercury content, meet RoHs requirements, LED light source is typically green.

Life:

LED life of up to 50,000 hours, or point that is light, there is no delay time, switching frequency does not affect the light source life.

Security:

Not easily damaged, green. Recyclable waste, no pollution; unlike fluorescent lamps contain mercury components panel, soft light, through the CE certification.

Wide scope of application:

Start at low temperature, normal and use. Common fluorescent panel lamp difficult to start at low temperatures, due to unique design, LED panel lights (special materials: aluminum shell + LGP + spread sheet), light emitted by the surface uniform light, look no glare, greatly reducing human eye injury, relieving eye fatigue, especially for hospitals.

Adaptation places:

Hospitals, offices, retail stores, supermarkets, schools, hotels, factories, car parks and other indoor places to use.

一、   Optical property &Technique parameter:

 

 Ⅰ.SMD LED Panel light

 

Models

Spec.

 (φ*H(MM))

Input Voltage

(AC V)

Power

(W)

Luminous Flux(LM)

SMD

 

LED

LED

 

Q’ty

Color

 

TEMP

Hole

Size(MM)

SL-RPL-6W-W-4INCH-5050

φ150*16.5MM

100~240

 

6

 

≥700

 

5050

 

35

 

5500K-6000K

 

127

SL-RPL-8W-W-5INCH-5050

φ180*16.5MM

100~240

 

8

 

≥840

 

5050

 

42

 

5500K-6000K

 

158

SL-RPL-10W-W-6INCH-5050

φ200*16.5MM

100~240

 

10

 

≥980

 

5050

 

49

 

5500K-6000K

 

180

SL-RPL-12W-W-8INCH-5050

φ250*16.5MM

100~240

 

12

 

≥1120

 

5050

 

56

 

5500K-6000K

 

229

 

Ⅱ.Operating Enviroment

Item

Requirement

Unit

Operating Voltage

AC110/220

V

Operating Frequency

50/60

Hz

Operating Temperature

-20~+60

Storage Temperature

-20~+80

Storage Humidity

﹤90

%

    

Ⅲ.Test Comtents

Item

Symbol

Min

Typ

Max

Unit

Input Voltage

Vin

/

110/220

/

V

Input Current

I

/

0.0151

/

A

Frequency

F

/

50/60HZ

/

Hz

Power

P

/

8W

/

W

Colour

/

/

RGB

/

/

Power Factory

PFC

/

0.6

/

/

Power Efficiency

eff

/

83

/

%

LED Current

I

/

60

/

MA

Color Temperature

CCT

/

/

/

K

Luminous Flux

LM

/

/

/

LM

 

Size for LED Round Panel Light:

      

 NOTES:

All the unit of the Size are MM ,Size Tolerance: ±0.5MM

 

 

The package picture:

 

                   

(1)Banket CAD Diagram

           

                    

         (2) Inner Size of Package CAD diagram           (3)Inner Size of Package CAD diagram      

NOTES:30PCS PER CARTON

  All the unit of the Size are MM ,Size Tolerance: ±0.5MM

 

 

 

 

 

 

 

 

Ⅳ. Luminance

  

 

 

 

Install schemes:

     1.Embedded wiring diagram as below:

                

NOTE :Enchase LED panel light in the opening ceiling, make the light block into the opening of ceiling

 

Installation note::

1 The LED round panel lights apply to power supply which is provided by our company, cut off the high voltage switch when installing this product.

2. This product is limited for indoor use, far away from heat, strong vibration source.

4. Please click product labels and product specification requirements of choosing the correct working voltage, and correct wiring method.

5. Please don't over water, don't knock, impact panel lamp, transit please affairs, please affairs heavy backlog take replays

6. To ensure the installed celing have 2 centimeters high spatial, lights can not be all installed at the celing of inside, or have heat wall, attention should be paid to low voltage and high-voltage connection separate wiring.

7. To ensure the wire for power supply is long enough, not by tension or tangential force. Install attachment to avoid excessive tension and don't make attachment knot. Output attachment must distinguish, don't confuse and other lamps and lanterns.

8. Connect the input wire of power supply swtch to main supply. Usually red, blue line for firewire for neutral, brown (black) line of landlines.

9. If you have any questions please contact us.

 

NOTE:

1. Don't secretly tear our label.

2. Non-professional persons (no electrical operation certificate) must not removed, maintenance. Our company has right to refuse to provide replacement or guarantee service to who removes, maintenance products without our permision.

 

You May Like